6) Quantum ST4Vilber LourmatThe fluorescence masterQuantum ST4 is an image acquisition system dedicated to the capture of
fluorescence gel images. Quantum ST4 offers exquisite precision and resolution,
which mean reliable results for both quantification and documentation.
The advanced imaging electronics has been developed by our experts especially
for your scientific applications. This association of our exclusive electronic,
high-
quality optics and advanced software delivers outstanding performance. With
Quantum ST4, you simply reach the lowest limits of detection on all of your
samples. systèmes d'imageries chemiluninescence gel docs documentations lourmat |
|  Quantum ST4.jpg) |
Request Information
Product Information Key features - PC based system for easy archiving and analysis
- Scientific Sony chip CCD camera
- 16-bit imaging
- Free software for image documentation, enhancement & analysis
- Autofocus and focusing gauge - Motorized or manual scientific zoom lens
- Multi-positions filter slide
- All the necessary information to ensure the optimum quality of your image
- GLP file
- Compact and robust darkroom
The largest excitation / emission palette- 14 illuminations options including blue, red and green sources
- Up to 6 filters at once
- Standardised filter size for enhanced compatibility
- Open to custom filters available from industry leader like Omega, Chroma, Semrock
- Compatible with Super-Bright and the F440 universal filter combination
- Multi format sample holding
Back to Top Quantum-Capt Software: fast, accurate and easy to use solutionQuantum ST4 is supplied with a complimentary software to perform analysis
such as molecular weight, band quantification, colony counting and distance
calculation. It also includes image enhancement features to enable editing of
comments, inversion, contrast / brightness adjustment as well as colorimetry.
Designed by molecular biologists, our softwares are intuitive and very easy to
use: just few clicks are necessary to obtain sophisticated results. Universal fluorescence configuration Thanks to the Universal configuration, only one camera filter is sufficient for
almost all fluorescent and visible applications. The Universal configuration
works with any kind of fluorescent dyes with emission starting from 450 nm
such as SYBR GreenTM, Sypro OrangeTM, or Texas RedTM. It avoids the
harassment and the cost of using several filters. The Universal configuration
is based on our Super-Bright transilluminator and our unique F-440 camera
filter. Image master Our exclusive Image Master
TM function helps you to obtain the optimum
image at a glance. For instance, it automatically monitors the maximum and
the minimum intensity obtained on the image, indicates its dynamic and warns
you about pixel saturation. Image Master
TM is simply perfect for quantification
and publication. It helps you to keep the control on the image, making sure
your image is always appropriate whatever its use. Accurate quantification - Access to the raw data
- Full resolution mode with total image integrity
- Scientific CCD camera
- Linearity & consistency
- 1.4 millions of details
- 4.8 OD – 65 384 grey levels
Bio-1D Quantification Software- Transform your 1D gel into 3D results with our unique 3D
- State of the art analysis algorithms
- Detect automatically the lanes and the bands with the one click Detector TM feature
- Exclusive Next TM tutorial mode for an incredible ease of use
- Work with virtually any kind of samples such as DNA, RNA, protein, polynucleotide, Petri dish, microtitration plates, plants and in-vivo images
- Ease your analysis by using the same template for the analysis of different images
Bio-1D is a sophisticated and intuitive analysis software designed for virtually
any fluorescence or chemiluminescence sample. The software combines the
power of a comprehensive set of analytical tools and automatic functions in an
incredibly easy to use environment.
Bio-1D modules: - Molecular weight
- Volume quantification for 1D
- Microtitration plate analysis
- Array analysis
- Free form object analysis
- Colony counting
- Image enhancement
- Results publishing
Back to Top
|
| Monochrome scientific grade CCD came
Real time and integration time | | 1.400.000 pixels – Sony chip
(1360x1024) | | True 16-bit, 65 536 grey levels. | | Ultra high sensitivity for fluorescence
Scientific grade camera - Chip quality: Grade 0, zero defect
Progressive scan – Low dark current
HAD (Hole Accumulation Diode) sensor
Continuous variable-speed shutter
USB2 interface
| | Scientific grade zoom lens
Manual (focusing gauge) or motorised configurations (autofocus) | | Quantum ST4 is supplied with the Quantum-Capt software for image enhancement and
basic image analysis. The Quantum ST4 images are compatible with Bio-1D and Bio-
Gene software for quantification: transform your 1D gel into 3D results. | | CN-1000 darkroom
Roll-out transilluminator
UV security switch
UV security timer
3 positions filter slide.
Overhead white light by fluorescent tubes
312nm transilluminator (6x-8watt)
Available filter size : 21x26cm or 20x20cm | CN-3000 darkroom
Roll-out transilluminator
UV security switch
UV security timer
6 positions filter slide.
Uniform white light or UV light epi-
illumination
Upgradable to StarLight module
312nm transilluminator (6x-8watt)
Available filter size : 21x26cm or 20x20cm |