Products
NanoPhotometer

ScanDrop
 
 
 
 

NanoPhotometer

Implen

Complete solution for ultra low and standard volume applications

nanodrop drop nano spectrophotomètre cuvette microliter integrated printer bluetooth

  • Nucleic acids: dsDNA, ssDNA, RNA, and Oligonucleotides
  • Labeling: efficiency dye incorporation rate for microarray experiments
  • Proteins: Bradford, Lowry, BCA, Biuret, and UV Protein (A280)
  • Cell density: for microbiology and cell culture

The outstanding technology combines ultra low and standard volume applications for improved concentration measurement and estimation of purity in one UV/Vis spectrophotometer. The fully developed software enables more user comfort with the established methods and assists with the predefined Functions self-programming to meet future needs. Various photometric functions, e.g. single and multi wavelength measurement combined with kinetic methods, opens up a wide range applications. The full wavelength scan (190 nm - 1100 nm) allows curve interpretation for attainment of more detailed scientific knowledge over whole spectrum.

NanoPhotometer

Request Information

Quantity



Product Information


Features

  • Cuvetteless ultra low volume measurements with integrated LabelGuard™ Microliter Cell (starting from 0.7µl)
  • Standard cuvette applications with quartz cells and plastic cuvettes
  • Ultra fast full spectrum scan in less than 4 seconds (200 nm – 950 nm)
  • Virtual dilution of up to 1:100, No dilution errors
  • Fully developed software Built-in methods and predefined functions assist self-programming
  • Kinetic function: Absorbance per minute, concentration, correlation factor
  • No computer necessary to operate, Direct data download option to PC via USB or Bluetooth
  • Minimal space requirements
Advanced Technology

Images

The NanoPhotometer™ spectrophotometer is a simple-to-use UV/Visible instrument. It is the perfect composition in highest quality to cover all photometric applications in molecular biology, biochemistry, and microbiology. The CCD array detector (1024 pixels) and the pulsed xenon lamp guarantee most accurate measurements. The spectrophotometer has no moving parts, which is the basis of the rapid scanning operating system within the range from 190 nm and 1100 nm. The high performance instrument operates with wavelength reproducibility (± 1 nm) and accuracy (± 2 nm) at a spectral bandwidth of 5 nm. Within the photometric range of - 0.3 to 2.5Absorbance, respectively 0 to 199%T, the NanoPhotometer TM performs with highest linearity and reproducibility. The back-lit liquid crystal display is very easy to navigate with the alphanumeric entry and navigation arrow keys on the hard wearing, spill proof membrane keypad After switching on the instrument will perform a series of self-diagnostic checks for wavelength calibrations.

Planview of the NanoPhotometer Function

Images

The sample is pipetted onto the centre of the measuring window. Due to the integrated beam deflexion and the use of fibre-optic light conductors the sample can be measured directly on the measurement window. Using one of the four available lids of the microliter cell (lid 10, lid 50 and optional lid 5 or lid 100) different liquid columns of defined pathlength are created. Virtual dilutions of up to 1/100 are generated in comparison to a standard 1 cm cuvette measurement, without a manual dilution of the sample. Dilution errors are avoided and the sample can be retrieved after the measurement.

Press Releases

NanoPhotometer Application Note - A synonym for spectrophotometric quantification of submicroliter and standard sample volumes with high reproducibility and linearity over a broad range View the PDF

Implen NanoPhotometer™ - a vital forensic tool View the PDF

Mexican Ministry of Agriculture and National Institute for Epidemiology buy Advalytix AmpliSpeed and Implen Nanophotometer to screen for H1N1 (Swine Flu) and agricultural pathogens View the PDF

Back to Top


Specifications

Photometric specifications
Photometric modeAbsorbance, %Transmission, concentration, scan, ratio, multi and single wavelength, kinetics in ∆Abs*factor/min
Kinetics mode Start time, end time, interval, numbers of points TBA.
Analysis modeLSQ, rate, factor, curv
Scan rangeFull wavelength scan 200nm – 950nm Wavelenght range 190nm - 1100nm
Slew rateMeasurement time for full spectrum acquired simultaneously in less then <5 sec
Photometric range -0.3 – 2.499 Abs0-199% T
Photometric Reproducibility ±0.003Abs (0 to 0.5Abs)±0.007Abs (0.5-1.0Abs) @ 260nm
Photometric Accuracy±0.005A or ±1% of the reading, whichever is the greater
Wavelength reproducibility< ±0.2nmthe greater
Wavelength accuracy ± 2 nm
Zero stability ±0.003Abs/hour after 20min warm up @ 340nm
Noise 0.002A rms at 0A @ 260nm0.005A (pk to pk) at 0A @ 260nm
Bandwidth 5 nm
Stray Light<0.5% at 220nm and 340nm NaNO2
Optical arrangements
Optical arrangements Dual channel Czerny Turner with flat grating, 1024 pixel CCD array
LampPerformance Verification
Lifetime10 power 9 flashes
Warranty 1 year
Performance Verification Auto diagnostics when switched on
Methods programming
Method storageUp to 90 user-defined methods
Built-in methods for nucleic acids (dsDNA, ssDNA, RNA, Oligos), labelling efficiency (dye incorporation for microarrays), proteins (Bradford, Lowry, BCA, Biuret, UV), bacterial cell density (microbiology)
Predefined functions forSelf-programming methods: single and multiple wavelength, concentration, wavelength scan, kinetics, standard curve, and ratio calculation
Standard cuvettes
Cuvettes cells 10mm cuvette cells with outside dimension 12.5mm x 12.5mm. Quartz SUPRASIL cells are recommended.
Cuvette compartment10mm cell (outside dimension 12.5mm x 12.5mm)
Cuvette storage 8 x 10mm cells
Input / output ports
USBUSB is standard for connection to a PVC for direct data download for spreadsheet calculations, printout and data storage
Built-In Printer Internal Serial interface to optional external printer. Graphics to be printed out on thermal high stability paper, 56mm wide, and 40 columns
BlueTooth Internal Serial interface to optional Blue Tooth wireless link for connection to a PC

Back to Top


Ordering

DescriptionCatalog no.Price
NanoPhotometer™ UV/Vis spectrophotometer for ultra low volume and standard cuvette applications with built-in computer, touch pad, USB port for data transfer, cables and manualB-80-3004-30TBD
NanoPhotometer™ UV/Vis spectrophotometer for ultra low volume and standard cuvette applications with built-in computer, touch pad, thermal paper printer, USB port for data transfer, cables and manualB-80-3004-31TBD
NanoPhotometer™ UV/Vis spectrophotometer for ultra low volume and standard cuvette applications with built-in computer, touch pad, USB port and Blue-Tooth connection for data transfer, data transfer software, cables and manual B-80-3004-33TBD
Accessories Available
DescriptionCatalog no.Price
Thermal Paper Printer module for the NanoPhotometer™ B-80-3004-32TBD
BlueTooth connection module for the NanoPhotometer™ (does not include PC Bluetooth card, please purchase through local dealer)B-80-3003-96TBD
NanoPhotometer™ software package for online data transfer to a PC (printing, data export to Excel, ASCII, etc.), including connection cable NP-SW100 TBD
Replacement Paper Rolls for Thermal Paper Printer B-80-3004-32 (pack of 5)VI-G1D-04712TBD
Dust cover for the NanoPhotometer™B-80-3004-02TBD
Certified Didymiumglasfilter for the control of wavelength and photometric accuracy for the NanoPhotometer™ NP-HDF100TBD
Quartz SUPRASIL, Macro Cell Light Path 10mm; Dimension: 45mm x 12.5mm x 12.5mm; Volume: 3500µl H-100-QSTBD
Quartz SUPRASIL, Semi-Micro Cell Light Path 10mm; Dimension: 45mm x 12.5mm x 12.5mm; Volume: 1400µl H-104-QSTBD
Quartz SUPRASIL, Ultra-Micro Cell Light Path 10mm; Centre Height 15mm; Dimension: 45mm x 12.5mm x 12.5mm; Filling Volume 180 µl, Chamber Volume: 160µl H-105.200-QSTBD
Quartz SUPRASIL, Ultra-Micro Cell Light Path 10mm; Centre Height 15mm; Dimension: 45mm x 12.5mm x 12.5mm; Filling Volume 120 µl, Chamber Volume: 100µlH-105.201-QSTBD
Quartz SUPRASIL, Ultra-Micro Cell Light Path 10mm; Centre Height 15mm; Dimension: 45mm x 12.5mm x 12.5mm; Filling Volume 70 µl, Chamber Volume: 50µlH-105.202-QS TBD
Hellmanex® II Liquid cleaning concentrate for glass, quartz cells and optical components, Selling unit: 1,3 kg PE bottle (1,0 l )H-320.001TBD

Back to Top