My Cart
My Quotes

Multi Crystal LB 2111 Gamma Counter (Discontinued)

Catalog Number:
81425
Availability: Out of stock
Please contact us

***This product has been discontinued***

 

_________________________________________________________________

Multi Crystal LB 2111 Gamma Counter

The Multi Crystal LB 2111 gamma counter is a compact, robust and easy-to-use instrument for most applications where -emitting isotopes are used.

The instrument can be operated in a stand-alone mode or can be hooked to a personal computer. In either of the options the user is guided through a clearly structured and easy-to-use assay setup. Templates facilitate the definition of new measurement protocols and data evaluation.

Sample loading is made easy and convenient by means of 12 position sample racks that are simply inserted into the matching boreholes of the detector crystals. Sample throughput is high as 12 tubes (or even 24 tubes with the extended model) can be measured at a time.

The absence of any moving parts and the robust electronics guarantee a long lifetime and error-free operation.

 

Sample Racks

The sample racks facilitate loading of 12 samples at a time in a most convenient way. With multiple racks all samples of a measurement campaign can be prepared in advance.

The sample rack concept has another important advantage: in case a tube is contaminated on the outside the contamination is never carried on to the instrument. The racks themselves can be cleaned and decontaminated. 

 

Detectors

The 12 detectors are made of high-quality NaI borehole “well type” crystal providing best measurement geometry for -emitters located in a sample tube. The crystals cover an energy range up to 500 KeV - suitable for the common isotopes, e.g. 125I, 57Co, 59Fe, 51Cr and 99Tc.

A thick lead shield of 6 mm, i.e. in total 12 mm of lead surrounding each of the detectors efficiently prevents crosstalk between the samples in the individual detectors.

For specific loading patterns any of the detectors can be disabled individually. Exchangeable plastic liners prevent detector contamination. 

 

instruments models

The Multi Crystal LB 2111 gamma counter is available as a 12-detector unit. To increase throughput a second detector block may be added resulting in a 24-detector instrument.

Both models can be operated stand alone or with the PC software LBIS.

 

Stand-alone operation

In this configuration a video terminal and a keyboard are connected to the gamma counter. A serial matrix printer is to be used for data output. The stand-alone configuration supports all requirements of a laboratory’s routine assays incl. raw data (CPM), RIA, IRMA, ratio and receptor type. 

 

Detector standardisation

The standardisation procedure corrects for slight variations in detector efficiencies. Either, a single tube containing the isotope e.g. 125I, is sequentially counted in each of the detectors or 12 tubes, each with the same amount of activity, are counted simultaneously in all 12 detectors.

Together with the standardisation the high voltage supply is optimised for each detector. 

 

Software features

LBIS immunoassay evaluation software

The LBIS software is a Windows® based instrument operation and data evaluation software with a graphical user interface. It supports all common types of competitive (RIA) and immunometric (IRMA) assays with superior curve fitting algorithms increasing the reliability of the calculated results at the lower concentrations.

LBIS supports worklist download and sample data upload to host computers. Up to 4 instruments connected to one PC can be run with one LBIS software. 

 

Instrument QC and IVD certification

Many laboratories are subject to quality manage- ment (QM) especially if assays for in vitro dia-gnostics (IVD) are performed.

The instrument’s operating software–both the stand alone version as well as LBIS–support the QM requirements, e.g. the German DIN 6855, by the Instrument QC functions.

The QC routines can be easily performed with 12 individual matched 125I or 57Co sources or even more conveniently with the long-lived 125I multi test source containing 12 sources of 2 KBq each.

The QC report includes absolute and relative detector count rates and efficiencies, background counts, the respective 2-sigma values and the means, CVs and matching of the detector efficiencies.

The Chi Square test is available as an additional routine to verify the instrument’s performance.

The Multi Crystal LB 2111 gamma counter holds the CE certification according to IVD Directive 98/79/EC (Annex I and Annex III sections 2 to 5).

 

High Throughput with 12 or 24 detectors

Sample throughput is high as 12 tubes (or even 24 tubes with the extended model) can be measured at a time, i.e. 200 samples can be measured within 17 min with a 1 min counting time per sample.

 

Applications

  • RIA and IRMA type immuno assays mainly with 125I:
  • Thyroid hormones e.g. T3, T4, TSH
  • Reproductive hormones e.g. LH, Estriol, FSH, Progesterone, Testosterone
  • Drug abuse screening
  • e.g. THC, Cocaine, Amphetamine
  • Allergy e.g. Histamines, IgE
  • Vitamins e.g. Vitamin D
  • Growth deficiency e.g. hGH
  • Neurotransmitter e.g. Serotonin, Dopamine
  • Bone and mineral metabolism e.g. Osteocalcin, Calcitonin
  • Gastric diseases e.g. Gastrin, Leptin, Ghrelin
  • Veterinary e.g. Canine T3, Canine TSH, Porcine GH
  • Tumour markers e.g. AFP, CEA, PSA
  • Neonatal screening e.g. neonatal TSH, neonatal T4
  • Diabetes e.g. Insulin, Glucagon, C-Peptide
  • Nephrology e.g. urinary Albumin
  • Iron metabolism e.g. Ferritin
  • Calcium metabolism e.g. Parathormone
  • Heart diseases e.g. Digoxin 
More Information
Shielding 6 mm lead shielding surrounding each detector, i.e. 12 mm lead between detectors
Energy range 0 => 500 keV
Isotopes 125I, 57Co, 51Cr, 59Fe, 99Tc all other isotopes within the energy range
Operational Modes CPM raw data : single or dual channel
CPM ratio : RAST, Cr-Release, T3 Uptake
RIA : e.g. FT4, single or dual channel
IRMA : e.g. TSH, single or dual channel
Combined RIA/CPM ratio : e.g. FTI
Combined RIA/IRMA : e.g. FT4/TSH <
Tubes ø 14.5 mm in rack ø 16 mm in bore hole
Efficiency 75 % for 125I - 2.5 % for 51Cr
Detector Crosstalk 0.413 % for 51Cr
Operating system Windows 8 / Window7 (64bit & 32bit) / XP / Vista
PC Requirements Pentium Processor, 500 MHz (or better), CD ROM drive, display 1024 x 768 (or better), USB
Interface RS-232
Power Supply 110 - 220 V +/- 10%, 50 - 60 Hz
Temperature Storage: 0 - 40°C Operation: 15 – 35 °C
Humidity 10 - 85% non-condensing
Regulations CE, UL, CSA
Order information

LB 2111 Gamma Counter RIA, 12 detectors, incl. terminal & printer, 230 V : 81425-10-230 
LB 2111 Gamma Counter RIA, 12 detectors, incl. terminal & printer, 115 V : 81425-10-115 
LB 2111 Gamma Counter LBIS, 12 detectors, incl. LBIS software, 230 V : 81425-11-230 LB 2111 Gamma Counter LBIS, 12 detectors, incl. LBIS software, 115 V : 81425-11-115 LB 2111 Gamma Counter RIA24, 24 detectors, incl. terminal & printer, 230 V : 81944-10 
LB 2111 Gamma Counter RIA24, 24 detectors, incl. terminal & printer, 115 V : 81944-20

LB 2111 Gamma Counter 24 basic, 24 detectors, 230 V : 81944-01

LB 2111 Gamma Counter 24 basic, 24 detectors, 115 V : 81944-02

24-pin matrix printer with accessories : 08687


12 position sample rack, 10 pcs. : 30002
Test source 129I : 08691


Test source 57Co : 23806


Multi-Test source 12-fold 129I :24831


PC immunoassay software LIBS : 21328


PC terminal software WinTerm : 29890
Vials 5 ml, 12x75 mm, 2000 pcs. : 09778

Write Your Own Review