Mon panier
Mes devis

Lumat LB 9510 Tube Luminometer

Numéro de catalogue:
71450
Disponibilité: En stock
Please contact us

Lumat Luminometer for Tubes

Ultrasensitive flash and glow assay readings

The Lumat LB 9510 offers the functionality, versatility and superior performance you can expect from a luminometer developed by Berthold Technologies. The optimized optical system provides true single photon counting combined with a low-noise photomultiplier tube for up to 6 decades of linear dynamic range. The new Lumat has all the key features needed for today’s research applications.

 

HIGHLIGHTS

Luminescence detection at its best

Thanks to a stringent selection of photomultipliers working in photon counting mode and more than 40 years of experience building luminometers, the new Lumat offers excellent luminescence sensitivity: <1 zmol firefly luciferase and <1 amol ATP/tube (high sensitivity model) can be reliably detected.

 

JET injectors - highest accuracy, speed and cell-friendliness

The Lumat can be equipped with up to 2 JET injectors with variable volumes. The ultra-fast injection speed of JET-injectors eliminates any delay between injection and measurement and is critical to measure fast reactions, e.g. for flash luminescence measurements.

Berthold Technologies' JET injectors use Teflon bellows for accurate and fast injections and guarantee most efficient mixing as well as extreme longevity.

  • Accurate pipetting of small volumina: regardless of whether you want to inject large or small volumes, JET injectors ensure high accuracy and more than 98% accuracy over the entire volume range
  • Low maintenance costs: frictionless operation for extended lifetime
  • Cell-friendly performance: cell-friendly materials and negligible shear forces enable worry-free injection of cell suspensions, e.g. in Aequorin-based calcium assays.

 

Convenient sample switching mechanism

The measurement of individual samples one after the other can be time-consuming. The Lumat has a turret mechanism that makes this job easier and increases your throughput. Thanks to its motor-driven revolving magazine mechanism based on a rotating chamber for two tubes (one for measuring and one for loading and unloading), so you can prepare and insert the next sample while the previous one is still measuring.

 

Convenient Software options

Berthold Technologies’ ICE software is a wizard-driven software that is very simple to use. There are several versions of ICE sotware available:

  • ICE Research for single, dual and kinetics measurements.
  • ICE Immunoassay for single measurements with curve fitting and cut-off evaluation.
  • ICE Advanced to combine all capabilities of both ICE Research and Immunoassay.

 

TECHNICAL DETAILS

Measurement

Detectors

Low-noise photomultiplier tube in single photon counting mode

Detection technologies

Luminescence

Measurement modes Endpoint, Kinetics
Spectral range luminescence 380-630 nm

 

Injectors

Injectors  

Up to 2 JET injectors with frictionless operation

Injector  volume

10-100 µL or 25-300 µL

Injector speed

200-440 µL/s

Injector accuracy

Better than 2% across the entire volume range

Injector precision

Better than 2% across the entire volume range

 

Sample formats

Tube formats                          

Luminescence tubes, 12 x 47 mm

Luminescence tubes, 12 x 55 mm

Luminescence tubes, 12 x 75 mm

Microcentrifuge tubes, 1, 1.5 and 2 mL

 

Performance

Luminescence sensitivity

Standard model: <5 amol ATP/tube

High-sensitivity model: <1 amol ATP/tube

Dynamic range

≥6 orders of magnitude

 

Operation

Interface Windows software, connected to computer by USB
Operating system Windows 10 or better
Available software packages  
  • ICE Research for single, dual and kinetics.
  • ICE Immunoassay for single measurements with curve fitting and cut-off evaluation.
  • ICE Advanced to combine all capabilities of both ICE Research and Immunoassay.
 

 

Additional Specifications

Regulations CE, NRTL
Power Supply 100 – 240 VAC ±10 %, 50/60 Hz
External auto ranging mains adaptor
Temperature tolerance

Storage: 0-40° C

Operation: 15-35° C

Transport: –20 °C to 50 °C

Humidity tolerance

10-80% non-condensing
Maximum relative humidity of 80 % for temperatures up to 31 °C; decreasing linearly to 50 %, relative humidity up to 40 °C

Altitude max. 2000 m (above sea level)

Dimensions (W x D x H)

240 x 280 x 220 mm

Weight

4 kg

Plus d’information
Unité de détection Tube photomultiplicateur à faible bruit en mode de comptage de photons individuels ; plage spectrale : 380 – 630 nm.
Detecteur Photomultiplicateur à canaux hautement sensible (CPM) - rapport signal/bruit optimal grâce à une réduction efficace du bruit (technologie de réduction du rapport signal/bruit).
Chambre de mesures r Motor driven rotating chamber for two tubes (one for measuring and one for loading/unloading)
Sensibilité 5 amol ATP
Plage dynamique (Linéarité) > 6 ordres de grandeur
Tubes Lumivials 12 x 47 mm (09777) Lumivials 12 x 55 mm (26152) Lumivials 12 x 75 mm (09778) Eppendorf tubes 1 mL, 1.5 mL and 2 mL
Unité d'injection Up to 2 (variable volume: 10 – 100 μL or 25 – 300 μl); JET injection technology; precision: >98 %; accuracy: >98 %
Interface USB
Système d'exploitation PC WinXP, WinVista, Win7
Type de PC requis Processeur Pentium, 500 MHz (ou mieux), lecteur de CD-ROM, affichage 1024 x 768 (ou mieux), port USB.
Source de courant 110 – 240 V, 50/60 Hz, 30 VA Adaptateur secteur externe à plage de tension automatique.
Certifications CE, UL
Plage de températures (°C) Stockage : 0 - 40 °C Fonctionnement : 15 - 35 °C
Humidité 10 à 85 % d'humidité relative, sans condensation.
Dimensions 240 x 280 x 220 mm (W x D x H)
Mesure unique 0.1 to 600 s
Mesure double each 0.1 to 600 s
Délai up to 600 s
Rédigez votre propre commentaire
Vous commentez :Lumat LB 9510 Tube Luminometer
Vous pourriez également être intéressé par le(s) produit(s) suivant(s)
Catalog Number Nom du produit Prix Qté
MBILUCY MBI Evolution LUCY Luciferase Assay Kit
Please contact us
Out of stock
71450-10 LB 9510 Lumat, w/o injectors, ICE software
Please contact us
71450-20 LB 9510 Lumat "Reportergene", w/ 2 injectors (100µl), ICE software
Please contact us
71450-21 LB 9510 Lumat "High sensitivity", w/ 2 injectors (100 µl), ICE software
Please contact us
71450-30 LB 9510 Lumat "Immunoassay", w/ 2 injectors (300 µl), ICE software
Please contact us