Mon panier
Mes devis

Lumat³ LB 9508 Tube Luminometer (Discontinued)

Numéro de catalogue:
54030
Disponibilité: En rupture de stock
Please contact us

Discontinued

Please see equivalent: Lumat LB 9510 Tube Luminometer

_____________________________________________

 

 

Setting Standards for Tube Luminometers

Already in its 3rd generation the Lumat³ offers the functionality, versatility and superior performance you can expect from an instrument developed by Berthold Technologies.

Maintaining the achievements of the prior generations like true single photon counting detector, frictionless JET injectors and the sample turret the Lumat³ sets a new standard with the ICE user software.

Wizard guided protocol definition, intuitive operation and especially today´s expectations for data transfer and storage are achievements every user will benefit from.

Sensitivity

True photon counting technology coupled with selected low noise photomultipliers and an optimised optical design is the only accepted way to achieve a low and stable background. This is a major parameter for high sensitivity in a luminescence measuring system enabling detection of extremely low amounts of analyte

  • less than 1 amol ATP per vial
  • less than 0.5 zmol Firefly luciferase per vial

ICE Software

The ICE software Research version supports ratio calculation for reporter gene applications, ADP and ATP determinations and kinetics functionality enzyme activities. Point-to-point curve fitting enables simple work with standard curves.

The ease of use during protocol creation, measurement and data export has been achieved with the wizard-driven and clearly structured software.

Unique Sample Loading – the Turret

The measurement chamber is designed to enable rotating sample transport. You can load a second sample while the first one is being measured, thus saving time which results in throughputs approaching those of an automatic instrument. The special design of measurement chamber provides superior light collection efficiency and contributes to the outstanding sensitivity.

Large Dynamic Range

The Lumat³ is able to count up to 25 Mio pulses per second equivalent to a dynamic range spanning 7 orders of magnitude. As no additional adjustments (such as gain and high voltage setting) are needed the Lumat³ offers convenience and security for every measurement over the entire life of the instrument.

Eppendorf Cups and Lumi Vials

In addition to all types of 12 mm Lumi vials the Lumat³ accepts Eppendorf tubes in 1 mL to 2 mL sizes.

Built-in Reagent Injectors

The instrument can be equipped according to needs with either no or 2 reagent injectors with variable volume in JET injection technology. You have the choice between a 100 µL and a 300 µL size injector. Superior accuracy and precision is combined with excellent mixing performance.

Variable injections speeds and "friendly" material enable even injection of live cells (e.g. in Aequorin based GPCR screening). The injector tips are located in reading position enabling the measurement of very fast labels, e.g. Acridinium esters, and to inject activators into a running kinetic.

Precision & Accuracy

Precise mechanics and the intrinsic stability of photon counting technology guarantee unrivalled repeatability of measurements. The instrument´s performance is stable over years. Time-consuming daily calibration is thus unnecessary and you can concentrate on other and more important duties.

Like all Berthold Technologies instruments the Lumat³ comes to your laboratory checked against a certified light source. With this reassurance you are able to work with accurate, traceable and comparable results.

Plus d’information
Unité de détection Tube photomultiplicateur à faible bruit en mode de comptage de photons individuels ; plage spectrale : 380 – 630 nm.
Chambre de mesures r Motor driven rotating chamber for two tubes (one for measuring and one for loading/unloading)
Sensibilité 5 amol ATP
Plage dynamique (Linéarité) > 6 ordres de grandeur
Tubes Lumivials 12 x 47 mm (09777) Lumivials 12 x 55 mm (26152) Lumivials 12 x 75 mm (09778) Eppendorf tubes 1 mL, 1.5 mL and 2 mL
Unité d'injection Up to 2 (variable volume: 10 – 100 μL or 25 – 300 μl); JET injection technology; precision: >98 %; accuracy: >98 %
Interface USB
Système d'exploitation PC WinXP, WinVista, Win7
Type de PC requis Processeur Pentium, 500 MHz (ou mieux), lecteur de CD-ROM, affichage 1024 x 768 (ou mieux), port USB.
Source de courant 110 – 240 V, 50/60 Hz, 30 VA Adaptateur secteur externe à plage de tension automatique.
Certifications CE, UL
Plage de températures (°C) Stockage : 0 - 40 °C Fonctionnement : 15 - 35 °C
Humidité 10 à 85 % d'humidité relative, sans condensation.
Dimensions 240 x 280 x 220 mm (W x D x H)
Mesure unique 0.1 to 600 s
Mesure double each 0.1 to 600 s
Délai up to 600 s
Rédigez votre propre commentaire
Vous commentez :Lumat³ LB 9508 Tube Luminometer (Discontinued)
Brochure (1.08 MB)
Vous pourriez également être intéressé par le(s) produit(s) suivant(s)
Catalog Number Nom du produit Prix Qté
MBILUCY MBI Evolution LUCY Luciferase Assay Kit
Please contact us
Out of stock