Junior LB 9509 Tube Luminometer
Junior LB 9509 Tube Luminometer
Junior is a small portable tube luminometer designed for all common applications using glow-type bioluminescent and chemiluminescent reagents. It can be used in a number of diverse fields of application including
- Biomedical research
- Clinical diagnostics
- Hygiene monitoring
- Process control in biotech
- Environmental monitoring of water quality
Excellent performance, its small size and low weight paired with battery operation make the Junior a highly versatile instrument which can be used in any location – the laboratory, on site or outdoors.
Features
Sensitivity
The detection unit of the Junior consists of a state-of-the art ultra-fast single photon counting photomultiplier with low noise. For demanding applications, a “high sensitivity” model with a specifically selected ultra-low noise detector is available driving the detection limit down to less than 50 Amol ATP.
Dynamic Range
Berthold Technologies single photon counting electronics and selected photomultiplier tubes with low noise and high saturation level ensure a wide dynamic range. The user will benefit by being able to measure low signals as well as high ones without the need to change any settings.
Reliability
A stringent selection of detectors ensures a neglectable day-to-day variation of instruments, thus providing a high reliability of the measurements.
Versatility
The unique design of the measuring chamber allows the use of a variety of different sample tubes and sizes. Besides the traditional lumi vials, micro centrifuge tubes (Eppendorf cups) and capped 4 mL vials can be used.
TECHNICAL DETAILS
Detectors | Photomultiplier tube in single photon counting mode |
Detection technologies | Luminescence |
Measurement modes | Endpoint |
Spectral range luminescence | 380-630 nm |
Tube formats |
|
Luminescence sensitivity |
|
Dynamic range | >6 orders of magnitude |
Interface |
|
Operating system | Windows 7 or better |
Regulations | CE |
Power Supply | 110-240 V, 50/60 Hz, 35 VA |
Temperature tolerance |
|
Humidity tolerance | 10-90% non-condensing |
Dimensions (W x D x H) | 150 x 280 x 170 mm |
Weight | 2 kg |
Unité de détection | Tube photomultiplicateur à faible bruit en mode de comptage de photons individuels ; plage spectrale : 380 – 630 nm. |
---|---|
Sensibilité | Under 3 fmol ATP |
Plage dynamique (Linéarité) | 6 ordres de grandeur |
Tubes | lumi vials 12 x 47 mm (09777) lumi vials 12 x 55 mm (26152) lumi vials 12 x 75 mm (09778) vials 15 x 42 mm (32737) Eppendorf tubes 2 mL Eppendorf tubes 1.5 mL capped vials 4 mL 14 x 54 mm |
Diaphonie | Low crosstalk due to crosstalk reduction design: 10-6 |
Type de PC requis | Logiciel terminal WinTerm (en option) pour le transfert de données vers un PC et l'exportation vers des feuilles de calcul Excel. |
Logiciel | Logiciel intégré opéré via un clavier à membrane, définition du temps de mesure (1 à 999 s), site d'échantillonnage, numéro d'échantillon, examen des résultats avec fonction de recherche, téléchargement des résultats sur un ordinateur. |
Mémoire | Jusqu'à 2 000 plus récentes (FIFO) |
Système d'exploitation | Logiciel terminal WinTerm (en option) pour le transfert de données vers un PC et l'exportation vers des feuilles de calcul Excel. |
Source de courant | 110 - 230 V; 50/60 Hz; 35 VA |
Certifications | CE |
Plage de températures (°C) | Stockage : 0 - 40 °C Fonctionnement : 15 - 35 °C |
Humidité | 10 - 90 %, sans condensation. |
Dimensions | 150 x 280 x 170 mm (W x D x H) |
Écran | illuminated graphic display, 128 x 64 pixel 3 LEDs (green, yellow, red) connected to software-set threshold levels |
Catalog Number | Nom du produit | Prix | Qté |
---|---|---|---|
MBILUCY | MBI Evolution LUCY Luciferase Assay Kit |
Out of stock
|