Mon panier
My Quote

Sirius 2 LB 9526 Tube Luminometer

Numéro de catalogue:
84018
Disponibilité: En stock
Estimated shipping date 01/09/2026, order this item in the next

Sirius 2 LB 9526 Tube Luminometer

High-Performance Tube Luminometer for Flash and Glow Luminescence Assays

Overview

The Sirius 2 LB 9526 is a high-performance tube luminometer developed by Berthold Technologies for sensitive detection of flash and glow luminescence signals. By placing the sample in close proximity to the detector and surrounding it with optimized light reflectors, the Sirius 2 maximizes light collection efficiency for exceptional sensitivity and signal-to-noise performance.

The instrument detects less than 0.5 zeptomoles of firefly luciferase and less than 1 attomole of ATP per tube, making it one of the most sensitive tube luminometers in its class. The low-noise photomultiplier tube is operated in photon counting mode, ensuring a very low background signal, excellent signal-to-noise ratio, and the highest linearity across a broad dynamic range.

Applications

The Sirius 2 LB 9526 supports a wide variety of luminescence-based research and diagnostic applications:

ATP bioluminescence assays
Firefly & dual luciferase reporter assays
Cell viability & proliferation studies
Caspase & apoptosis detection
Chemiluminescent immunoassays
Water toxicity & environmental monitoring
Fungal & bacterial bioluminescence
Kinetic luminescence measurements

Key Features

  • Low-noise photomultiplier tube in single photon counting mode
  • Detects <0.5 zmol firefly luciferase and <1 amol ATP per tube
  • 6 orders of magnitude linear dynamic range
  • Optimized light reflectors for maximum photon collection efficiency
  • Outstanding sample format flexibility: tubes, vials, and Petri dishes
  • Automatic quickstart — measurement initiates when the sample drawer closes
  • Automatic light shutter protects the detector from ambient light
  • No long delay required after drawer closure — immediate measurement readiness
  • Intuitive 7-inch capacitive touchscreen with gesture control
  • Optional integrated computer for standalone operation without external PC
  • Up to 2 syringe-type automatic reagent injectors (20–500 µL)
  • Data export to USB stick or network printer in CSV, PDF, and HTML formats

Sample Format Flexibility

The Sirius 2 sample chamber is engineered for both performance and flexibility. From small microcentrifuge tubes to 20 mL scintillation vials and 35 mm Petri dishes, the instrument accommodates the sample format that best fits your application without compromising detection sensitivity.

  • Standard luminescence tubes, 12 × 55 mm
  • Standard luminescence tubes, 12 × 75 mm
  • Microcentrifuge tubes, 1.5 mL and 2 mL
  • Scintillation vials, up to 20 mL
  • 35 mm Petri dishes

Optional sample holders enable accurate injector positioning for both microcentrifuge tubes and standard luminescence tubes, ensuring precise reagent delivery into the sample regardless of vessel format.

Automatic Quickstart

A standout feature of the Sirius 2 is its automatic quickstart functionality. Closing the sample drawer automatically initiates the measurement sequence — no button press is required. An integrated automatic light shutter protects the highly sensitive photomultiplier from ambient light exposure, eliminating the need for a long post-closure delay that is typically required with other tube luminometers to allow background levels to stabilize.

Immediate Measurement Readiness: Because the detector is shielded from ambient light the moment the drawer closes, the Sirius 2 is ready to measure immediately. This eliminates the need to set extended pre-measurement delays, capturing fast kinetic events from the very first second and improving throughput for flash luminescence assays.

Touchscreen Operation & Software

The Sirius 2 is controlled through an intuitive 7-inch capacitive touchscreen operated by familiar touch gestures. The easy-to-use onboard software provides advanced features including handling of replicates, dual assay calculations, and graphical display of results.

Two system configurations are available:

  • PC-Controlled: Connected to a Windows computer via USB, with software options including Quick Measurement, Single Assay, Dual Assay, Single Kinetics, Multiple Kinetics, and Cut-Off protocols.
  • Standalone (Integrated Computer): The optional built-in computer runs the full software suite directly on the instrument, featuring Quick Measurement, Single Assay, and Dual Assay protocols without requiring an external PC.

Data can be downloaded easily onto a USB stick, sent to a network or USB printer (PCL6 or PostScript 3 compatible), or exported in CSV, PDF, and HTML formats for further analysis in Excel or other programs.

Flexible Injector Solutions

The Sirius 2 can be equipped with up to two syringe-type automatic reagent injectors. The exceptionally broad injection volume range of 20–500 µL allows the system to adapt to virtually any flash luminescence assay requiring rapid reagent addition.

Ready-to-use sample holders ensure precise injector alignment for 1.5 mL and 2 mL microcentrifuge tubes, as well as for 55 mm and 75 mm luminescence tubes in the standard 12 mm diameter format.

Technical Specifications

Detection
Detector Low-noise photomultiplier tube in single photon counting mode
Detection Technology Luminescence
Spectral Range 300 – 600 nm
Luminescence Sensitivity < 1 amol ATP/tube (ATP HS assay); < 0.5 zmol firefly luciferase
Dynamic Range 6 orders of magnitude
Measurement Modes
Available Modes Endpoint, Kinetics, Multiple Kinetics
Injectors (Optional)
Number of Injectors Up to 2 syringe-type automatic injectors
Injection Volume 20 – 500 µL
Sample Formats
Compatible Vessels Luminescence tubes 12 × 55 mm and 12 × 75 mm; Microcentrifuge tubes 1.5 mL and 2 mL; Scintillation vials up to 20 mL; 35 mm Petri dishes
Software & Interface
Interface USB (PC-controlled); Optional integrated computer with built-in software
Display (Integrated Computer) 7-inch capacitive touchscreen, gesture control, 480 × 800 pixels
External Interfaces (Integrated Computer) 2× USB 2.0, 1× Ethernet (RJ-45)
Printer Interface Network or USB printing (PCL6 or PostScript 3)
Data Export Formats CSV (Excel), PDF, HTML
Available Protocols (PC Software) Quick Measurement (included); Single Assay, Dual Assay, Single Kinetics, Multiple Kinetics, Cut-Off (optional)
Available Protocols (Built-In Computer) Quick Measurement, Single Assay, Dual Assay
System Requirements
Power Supply 110 – 240 V, 24 V / 2.5 A DC
Operating Temperature 15 – 35°C
Storage Temperature 0 – 40°C
Operating Humidity Up to 70%, non-condensing
Storage Humidity Up to 80%, non-condensing
Physical Specifications
Dimensions (W × D × H) 349 × 150 × 241 mm
Weight 3.6 kg
Plus d’information
Format d'échantillon12 x 75mm or 55mm tubes, 1.5 and 2ml microfuge tubes, 35mm culture dishes, liquid scintillation vials up to 20ml. Injection operation with 12 x 55 and 12 x 75mm tubes and 1.5 and 2.0ml Microfuge® tubes
DetecteurPMT (tube photomultiplicateur) de comptage de photons, plage spectrale : 300–600 nm
Chambre de mesuresRetractable drawer with interchangeable reflectors and sample adapter
SensibilitéUnder 1,0 amol ATP
Plage dynamique (Linéarité)6 ordres de grandeur
Injecteurs (Maximum)0, 1, 2 (mise à niveau possible)
Volume d'injection 20–500 μl réglable par pas de 1 μl
TubesChemically inert PTFE tubing and connections (PTFE or KEL-F)
InterfaceInterface USB ou RS 232 pour connexion PC
Source de courantAlimentation de bureau et cordon d'alimentation. 100–240 V CA, 24 V CC/2,5 A.
Plage de températures (°C)Stockage : 0 - 40 °C Fonctionnement : 15 - 35 °C
Humidité10 - 90 %, sans condensation.
Dimensions45.6 x 34.9 x 15 cm/ 18 x 13.7 x 5.9 inch
Écran 7” capacitive touch, gesture control, 480 x 800 pixels
Fonctionnement autonomeIntegrated computer with built-in software
Protocoles logicielsQuick Measurement, Single Assay, Dual Assay and Wash & Prime protocol
Interfaces externes2x USB 2.0, 1x Ethernet
Interface d'imprimante.Network or USB printing (PCL6 or Postscript 3)
Exportation de donnéesBy USB memory stick; CSV (Excel), PDF, HTML formats
Rédigez votre propre commentaire
Vous commentez :Sirius 2 LB 9526 Tube Luminometer
Vous pourriez également être intéressé par le(s) produit(s) suivant(s)
Catalog NumberNom du produitPrixQté
MBILUCYMBI Evolution LUCY Luciferase Assay Kit
Out of stock