My Cart
My Quotes

ScanDrop 250 Microvolume spectrophotometer (Discontinued)

Catalog Number:
844-00202-2
Availability: Out of stock
Please contact us

This product has been discontinued.

Please see equivalent: Scandrop2.

 

___________________________________________________________________________________________________________

Biometra - Analytik Jena - ScanDrop

The ScanDrop combines the easy measurement of micro litre volumes down to 0.3 μl with a standard measuring position for 10 mm cuvettes. This feature offers an exceptionally versatile instrument for daily routine. The modular system is either available as single micro litre instrument, as standard 10 mm position instrument or as a combination of both. Unlike other systems no warm up time is necessary. Almost immediately after switching on the instrument it is ready-to-use thanks to a long-life xenon flash lamp. One additional highlight is the new portable user-interface HID-Pro 320 with a 5.7” color touch screen, which turns the ScanDrop into a fully functional and space-saving stand alone system.

 

Features

  • Combination of two generations of spectrophotometer
  • Measurement of micro litre volumes down to 0.3 μl
  • 16 channels per CHIPCUVETTE® with fully automated measuring of up to 32 positions at path length of 0.1 or 1.0 mm
  • Automated sample positioning (CHIPCUVETTE®)
  • Measuring position for 10 mm cuvettes
  • Maintains best user and sample protection
  • No evaporation
  • No cross-contamination
  • No carry-over effects
  • Easiest sample recovery
  • Suitable for multi-channel pipettes
  • Powered by SPECORD® technology
  • High-precision optics with aberration-corrected grating

 

Reliable, versatile and robust

The ScanDrop uses an unique patented CHIPCUVETTE®, which allows the user the easiest and convincing measurement of sample volumes even down to 0.3 μl. The CHIPCUVETTE® provides steady measuring conditions, as for example path lengths, what leads to enhanced eproducibility compared to other available “open drop” or “micro litre” systems. It also maintains the best user and sample protection. Evaporation of sample solvent, the risk of cross-contamination or carryover effects are completely eliminated. By using this new chip technology the sample can be easily recovered after measurement or even just kept stored. The CHIPCUVETTE® provides 16 separate micro channels and is suitable for multichannel pipettes. Its technology ensures precise UV VIS absorption measurements between 190 nm and 720 nm.

 

Fully automated measurement

The CHIPCUVETTE® is convenient and easy in handling due to the fully automatic movement and measurement of preprogrammed measuring positions. Up to 32 measurements during one run are possible, whereby a repeat determinationof one sample at two different path lengths can be performed. In case of unknown sample concentrations, this feature will offer a matchless advantage.

High-precision optics

The polychromator system, designed to work without any movable components, is the heart of the ScanDrop. His high-precision optics consists of an aberration-corrected grating, a mechanical slit and the diode array detector. Encased in a rugged quartz-ceramic body, it is permanently adjusted, fixed and insensitive to external influences.

 

PC controlled or stand alone

The ScanDrop is controlled either by PC or by a new portable user-interface with touch screen. The accordant measuring and analyzing software ASpect Nano is included into the scope of the delivery. This software provides several modules, which fulfill the requirements of each user. The method module, allows the selection of any pre-programmed method for nucleic acid and protein analysis. Using the formula module, every user can compile, store and reuse customized computation formulae and the quantification module offers the automatically calculation of unknown concentrations by creating a calibration curve containing standard samples. Lots of typically used methods are pre-programmed available. The formula module will combine up to ten fixed wavelengths mathematically and the quantification module chooses between two calibration curves: one measured at 0.1 mm and one measured at 1.0 mm path length.

 

External user-interface HID-Pro 320

The new portable user-interface HID-Pro 320 makes a PC superfluous and operations exceptionally easy. Through its extra large 5.7” touch screen no keyboard or mouse is required for operation. The Windows CE based software convince with typical Windows functions, feeling and a clearly arranged menu bar. The HID-Pro 320 consists a LAN and USB port for best connectivity. The HID-Pro 320 is also applicable with other instruments from Analytik Jena | bio solutions as the new SpeedCycler2 thermal cycler.

 

ScanDrop software

Methods can be individually stored and sorted in directories of choice. In addition a quick-start menu is selectable for frequently used methods. Exchange of methods to other systems or export of analysis data is not limited through a USB and LAN port. This also allows the direct connection of a printer. The operation language can be easily changed by a click of a button.

More Information
Optical principle Powerful diode array spectro-photometer for the UV VIS range
Optical system Polychromator system
Light Source Xenon flash lamp
Wavelength range 190 - 720nm
Measuring time 1 sec
Base line noise (RMS at 500 nm) 0.001 A
Base line stability 0.001 A
Wavelength Accuracy ± 2nm
Photometry UV 0.02 A VIS 0.01 A
Linearity (±) At 350 nm to approx. 2 A
Stray Light 200 nm 2.0%T 220 nm 0.5%T 340 nm 0.5%T
Long term stability 0.002 A/h
Sample-temperature control Approx. 4 - 90°C optional
Instrument operation +15°C to 35°C Rel. humidity max. 90% at 30°C
Scan application Simultaneous
Mode Energy, Absorption, Transmission
Net Weight Approx. 5 kg
Dimensions Approx. 240 x 170 x 200 mm
Power Supply 110 - 220 V +/- 10%, 50 - 60 Hz
Controls Via HID-Pro 320 or PC controlled
Software ASpect Nano
PC interface USB port or R S232 interface
Warranty 1-year parts and labor
Write Your Own Review