My Cart
My Quotes

Tristar 5 Multimode Reader

Catalog Number:
69185
Availability: In stock
Please contact us

Tristar 5 Multimode Reader

Application flexibility you can count on

The Tristar 5 is a modular high-performance microplate reader equipped with independent, user-selectable filters and monochromators on both, the excitation and emission side for any measurement.

This guarantees both, flexibility and sensitivity whenever you need it. The system supports advanced detection modes such as TRF and TR-FRET, and FP as well as specific assays like BRET/BRET2, NanoBRET™ , Lantha-Screen® or AlphaScreen®.

 

HIGHLIGHTS

DETECTION TECHNOLOGIES

The Tristar 5 Multimode Microplate Reader provides you with application flexibility for today, tomorrow, and beyond to master your changing plate reading applications. The system supports the following wide range of detection modes:

  • Absorbance (UV/VIS)
  • Fluorescence Intensity (including FRET)
  • Luminescence (including BRET and BRET2)
  • Time Resolved Fluorescence (TRF)
  • Time Resolved FRET (TR-FRET / HTRF®)
  • Fluorescence Polarization
  • AlphaScreen®

 

FlexTec Optics – when flexibility AND sensitivity count

The Tristar 5 system is equiped with FlexTec Optics, offering you the best of two worlds – benefit from the flexibility to easily select a discrete wavelength and perform spectral scans for both, excitation and emission using its built-in monochromator technology. Or optimize your assays´ sensitivity by utilizing the system filter sliders for excitation and emission. Or mix both technologies if required: the Tristar 5 delivers both, flexibility and sensitivity in a single system.

The Tristar 5 employs up to two double monochromators providing blocking properties needed in sensitive fluorescence assays. Both monochromators are equipped with software driven continuous bandwidth variation to optimise the instrument for the specific demands of different assay conditions.

Berthold´s flexible monochromator technology offers you variable bandwidths from 4-12 nm in excitation and 8 – 22 nm for emission, selectable in 1 nm increments.

 

ONE-4-ALL Optics - uncompromised performance

Our patented ONE-4-ALL optics have been optimised to combine the stability and user-friendliness of a multimodal optical system with the sensitivity and versatility of dedicated optical devices.

ONE-4-ALL optics work for both filter- and monochromator-based applications, so there´s never a compromise in performance in any mode.

 

High-performance filter system - when sensitivity counts

The quick-change filter technology of the Tristar series provides you with the flexibility required to meet your application needs: up to 40 different excitation and emission filters can be easily mounted on exchangeable filter slides.

The filters are characterized by high transmissions properties which can be up to 25-fold that of monochromators. Technologies like Time-Resolved Fluorescence (TRF) can be measured more efficiently with filters.

Furthermore, filters with a large bandwidth are available to analyze fluorophores with wide spectra and all luminescence-based assay requiring to use filters, e.g. BRET, BRET2 or NanoBRET™ assays.

 

Ergonomic design - supporting your workflows

The ergonomic design of the system provides full front access for all key operations (e.g. plate loading, filter change and connecting reagents). Reagent vials can be stored in an integrated front compartment, providing easy access and visibility.

It contains a removable trough that can be filled with water or ice to keep all reagents cooled. Different reagent tube holders are available to ensure secure handling of valuable reagents. The system has a flat surface on its top, providing enough space to put down a laptop.

 

Powerful crosstalk control – reliable results

Do you often see a few high-intensity samples surrounded by wells of low-intensity when running your samples?  Then you´re potentially affected by a phenomenon called crosstalk, that can produce wrong results and, hence, wrong conclusions. The crosstalk reduction design of the Tristar 5 does almost eliminate this problem: with a crosstalk of 10-6, you never have to worry about the position of your high-intensity samples in your plate.

 

JET injectors: highest accuracy, speed and cell-friendliness

The Tristar 5 can be equipped with up to 3 JET injectors with variable volumes in pre-measurement or measurement position. The ultra-fast injection speed of JET injectors eliminates any delay between injection and measurement and enables measurement of fast reactions, e.g. flash luminescence.

Berthold Technologies' JET injectors use Teflon bellows for accurate and fast injections and guarantee most efficient mixing as well as extreme longevity.

  • Highest accuracy and reproducibility - 98 % accuracy over the entire volume range
  • Low reagent consumption - Low dead volume. Recovers up to 60 % of the reagent in the injector line. A single priming sequence is sufficient to achieve a 99 % homogeneous mix at the tip.
  • Low maintenance costs – friction-free operation enables more than 3 million injections without mechanical failure.
  • Optimal performance in flash-kinetics - ultra-fast injection enables the measurement of the first 150 ms of a kinetic assay (e.g. Fura-2 or Acridiniumester-assys).
  • Worry-free injection of cell suspensions - negligible shear forces ideal when working with living cells, e.g. in Aequorin-based calcium assays

 

Convenient Software options

Choose between different software options according to your application needs:

ICE Software

  • ICE software is an intuitive, wizard-guided software that walks you through the entire process of setting up your system, collecting your data and reporting the results. The software package is as flexible as your research thanks to the many setting options and freely configurable combinations of operating sequences.

MikroWin Software

  • The MikroWin software is a complete software solution providing instrument control, data collection, analysis and reporting. The software is available in different versions, reflecting different user needs. The complete Advance version of the software provides 21 CFR Part 11 compliance and additional QC features like audit trail or configurable user hierarchies.

 

Technical Details

Detectors
  • Low-noise photomultiplier tube that can operate in single photon counting mode and in our advanced Pulse Height Detection mode
  • Photodiode for absorbance
Detection technologies (configuration-dependent)
  • UV-VIS Absorbance
  • Luminescence
  • BRET
  • Fluorescence
  • FRET
  • Time-Resolved Fluorescence
  • TR-FRET and HTRF®
  • AlphaScreen®
  • Fluorescence Polarization
Measurement modes Endpoint, Kinetics, Repeated, Spectral scan, Area scan (up to 100 x 100 points per well)
Bottom reading Yes (configuration-dependent)
Filters High quality interference filters
Filter handling Easy to change filter slides with up to 5 filters per slide, additional slides available
Monochromator Optional double 3D monochromator for absorbance, excitation and emission, high transmission (F number: 2.7)
Monochromator bandwidth Software-controlled variable bandwidth, 4-22 nm (1 nm increments)
Monochromator stray light 10-6
Optical system ONE-4-ALL optics
Light source Xenon flash lamp
Spectral range Absorbance 200-1000 nm
Spectral range Luminescence

Standard: 280-650 nm

FL models: 280-850 nm
Spectral range Fluorescence

Excitation: 230-1000 nm

Emission, standard: 280-650 nm

Emission, FL models: 280-850 nm
Injectors Up to 3 JET injectors with frictionless operation
Injector volume 10-100 µL in 1 µL steps
Injection speed 200 – 440 μL/sec
Injector accuracy Better than 2%
Injector precision Better than 2%
Microplate formats 6- to 384-well
Plate height adjustment 3 different frames depending on plate type
Additional sample formats (optional)
  • µDrop plate for microvolumes
  • Adapter for cuvettes
  • Adapter for petri dishes
  • Adapter for Terasaki plates
Shaking Linear, orbital, double orbital, with selectable speed and diameter
Temperature control From ambient +5° to 45° C, includes additional cooling for the photomultiplier
Gas connection Yes (optional)
Absorbance precision Better than 0.6%
Absorbance accuracy Better than 2%
Luminescence sensitivity <6 amol (0.03 pM) ATP/well (96-well plate)
Fluorescence sensitivity <7 amol Fluorescein/well (384-well small volume plate)
TRF sensitivity <5 amol Eu
Crosstalk 10-6 (black plates)
Dynamic range >6 orders of magnitude
0-3.5 OD
Interface Windows software, connected to computer via USB
Operating system Windows 10
Available software packages LightCompass®: flexible software for data acquisition, analysis and reporting. 
Regulations CE, NRTL
Power Supply 110-240 VAC ± 10%
50/60 Hz
Class I
Operating Voltage 24 VDC ± 5%
Power consumption 140 VA
Temperature tolerance Storage: 0-40° C
Operation: 15-35° C
Humidity tolerance 10-80% non-condensing
maximum relative humidity of 80% for temperatures up to 31°C
decreasing linearly to 50% relative humidity up to 40°C
Altitude max 2000 m (above sea level)
Dimensions (W x D x H) 391 x 470 x 395 mm
Weight approx. 32 kg
More Information
Wavelength Selection 2 Double monochromators
Measurement Technologies Luminescence BRET, BRET² Fluorescence (top) FRET Absorbance UV & VIS Time-Resolved Fluorescence TR-FRET / HTRF® FP (Fluorescence Polarization) AlphaScreen®
Luminescence 6 amol/well ATP (96 well)
Fluorescence < 7 amol/well FITC (384sv)
Absorbance Range Accuracy better 2% Precision better 0.6%
Time-Resolved Fluor. < 5 amol/well
Dynamic range (linearity) 6 orders of magnitude (photon counter) 0-3.5 OD (photodiode)
Crosstalk 5 x 10-6
Injection unit up to 3 injectors, JET injection technology variable volumes: 10 – 100 μL speed 200 – 440 μL/sec accuracy better 2% (over entire range of volume) precision better 2% (over entire range of volume) injections into microplates with up to 384 wells
Shaking 3 modes, variable amplitude and speed
Temperature Control +5°C above room temperature up to 45°C
Microplate Formats 6 to 384 well, solid and strip, Dimensions 128 x 86 mm (L x W) height 14.0 – 21.0 mm (adapters necessary) Petri dishes 35 and 60 mm Eppendorf μPlate G 0.5 Standard cuvettes (with cap)
Interface USB
PC operating system Windows 7 (32/64 bit), Windows 10 (32/64 bit)
PC Requirements Pentium like CPU (2 GHz or better / Intel Core iX recommended), 1 free USB port
Regulations CE, NRTL
Power Supply 100 – 240 VAC ±10% 50 / 60 Hz Class I
Voltage 24 VDC ± 5%
power consumption [W] 140 VA
Dimensions 391 x 470 x 395 mm
Detector Low-noise photomultiplier tube in dual mode, spectral range 280 - 650 nm (up to 850 nm with extended range PMT) Photo diode: spectral range 200 – 1000 nm
Light Source Xenon flash lamp
Wavelength range 200 - 1000nm
Write Your Own Review
You're reviewing:Tristar 5 Multimode Reader
You may also be interested in the following product(s)
Catalog Number Product Name Price Qty
69185-10 LB 942 Tristar 5 "Research" Multimode Microplate Reader for UV/VIS applications, user selectable filters and monochromator, ICE-software package
Please contact us
69185-15 LB 942 Tristar 5 "Advanced Performance" Multimode Microplate Reader for UV/VIS applications, user selectable filters and monochromators, temperature control, bottom reading, ICE-software package
Please contact us
69185-25 LB 942 Tristar 5 "Research Performance FL" Multimode Microplate Reader for UV/VIS applications (up to 850 nm), user selectable filters and monochromator, temperature control, bottom reading, ICE-software package
Please contact us
69185-30 LB 942 Tristar 5 "Research Plus" Multimode Microplate Reader for UV/VIS applications, user selectable filters and monochromator, temperature control, ICE-software package
Please contact us
69185-35 LB 942 Tristar 5 "Advanced" Multimode Microplate Reader for UV/VIS applications, user selectable filters and monochromators, ICE-software package
Please contact us
69185-45 LB 942 Tristar 5 "Research FL" Multimode Microplate Reader for UV/VIS applications (up to 850 nm), user selectable filters and monochromator, ICE-software package
Please contact us
69185-50 LB 942 Tristar 5 "Research FL" Multimode Microplate Reader for UV/VIS applications (up to 850 nm), user selectable filters and monochromator, ICE-software package
Please contact us
69185-55 LB 942 Tristar 5 "Advanced Plus" Multimode Microplate Reader for UV/VIS applications, user selectable filters and monochromators, temperature control, ICE-software package
Please contact us
Out of stock