RV 3 with Dry Ice Condenser (Manual Lift)
RV 3 with Dry Ice Condenser
The rotary evaporator RV 3 is the manual basic model in the family of IKA Rotation Evaporators. It finds a multitude of uses in the chemical, pharmaceutical, and biotechnology industries, in research and development, in manufacturing and quality assurance, in laboratories, and in plant construction. Digital displays for speed and heating bath temperature enable optimum control of all distillation processes.
heating bath with 4 l volume
integrated safety lift-out function in case of power failure
water/oil heating bath with carrying handles
locking button for fixing heating bath temperature
locking mechanism: red indicator shows unlocked position of the vapor tube
flask clamping mechanism with integrated push-off function for easy exchange of evaporation flasks
manual lift for precise positioning of the glassware
adjustable immersion angle
single-handed manual lift handling, suitable for left and tight-handed operators
speed range: 5 - 300 min-1
low device voltage (24V) ensures user safety
compatible with the entire range of IKA RV 10 glassware
Type of cooling
Dry ice condenser
Cooling surface
620 cm2
Motor principle
DC
Speed range
20 - 300 rpm
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Lift
manual
Stroke
150 mm
Heating temperature range
room temp. - 99 °C
Dimensions (W x H x D)
440 x 530 x 330 mm
Weight
28.3 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 20
Voltage
100 - 240 V
Frequency
50/60 Hz
Power input
1400 W
More Information
Cooling System Type
Dry ice condenser
Cooling surface
620 cm2
Drive Motor
Brushless D.C Motor
Reversible direction of rotation
No
Lift
Manual
Stroke
150 mm
Speed Range
20 - 300 RPM
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Temperature range (°C)
Ambient to 99°C
Heating bath temperature range
room temp. - 99 °C
Dimensions without glassware
440 x 530 x 330 mm
Ambient Operating Range
5 - 40°C
Permissible relative humidity (%)
80%
Weight of evaporator incl. heating bath without glass parts
28.3 kg
Protection class DIN EN 60529
IP20
Rated voltages
100 - 240 V
Frequency
50 - 60 Hz
power consumption [W]
1400 W
Get a Quote for
Country
Afghanistan
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua and Barbuda
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Bahamas
Bahrain
Bangladesh
Barbados
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bosnia and Herzegowina
Botswana
Bouvet Island
Brazil
British Indian Ocean Territory
Brunei Darussalam
Bulgaria
Burkina Faso
Burundi
Cambodia
Cameroon
Canada
Cape Verde
Cayman Islands
Central African Republic
Chad
Chile
China
Christmas Island
Cocos (Keeling) Islands
Colombia
Comoros
Congo
Congo, the Democratic Republic of the
Cook Islands
Costa Rica
Cote d'Ivoire
Croatia (Hrvatska)
Cuba
Cyprus
Czech Republic
Denmark
Djibouti
Dominica
Dominican Republic
East Timor
Ecuador
Egypt
El Salvador
Equatorial Guinea
Eritrea
Estonia
Ethiopia
Falkland Islands (Malvinas)
Faroe Islands
Fiji
Finland
France
France, Metropolitan
French Guiana
French Polynesia
French Southern Territories
Gabon
Gambia
Georgia
Germany
Ghana
Gibraltar
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Guinea
Guinea-Bissau
Guyana
Haiti
Heard and Mc Donald Islands
Holy See (Vatican City State)
Honduras
Hong Kong
Hungary
Iceland
India
Indonesia
Iran (Islamic Republic of)
Iraq
Ireland
Israel
Italy
Jamaica
Japan
Jordan
Kazakhstan
Kenya
Kiribati
Korea, Democratic People's Republic of
Korea, Republic of
Kuwait
Kyrgyzstan
Lao People's Democratic Republic
Latvia
Lebanon
Lesotho
Liberia
Libyan Arab Jamahiriya
Liechtenstein
Lithuania
Luxembourg
Macau
Macedonia, The Former Yugoslav Republic of
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Micronesia, Federated States of
Moldova, Republic of
Monaco
Mongolia
Montserrat
Morocco
Mozambique
Myanmar
Namibia
Nauru
Nepal
Netherlands
Netherlands Antilles
New Caledonia
New Zealand
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
Northern Mariana Islands
Norway
Oman
Pakistan
Palau
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn
Poland
Portugal
Puerto Rico
Qatar
Reunion
Romania
Russian Federation
Rwanda
Saint Kitts and Nevis
Saint LUCIA
Saint Vincent and the Grenadines
Samoa
San Marino
Sao Tome and Principe
Saudi Arabia
Senegal
Seychelles
Sierra Leone
Singapore
Slovakia (Slovak Republic)
Slovenia
Solomon Islands
Somalia
South Africa
South Georgia and the South Sandwich Islands
Spain
Sri Lanka
St. Helena
St. Pierre and Miquelon
Sudan
Suriname
Svalbard and Jan Mayen Islands
Swaziland
Sweden
Switzerland
Syrian Arab Republic
Taiwan, Province of China
Tajikistan
Tanzania, United Republic of
Thailand
Togo
Tokelau
Tonga
Trinidad and Tobago
Tunisia
Turkey
Turkmenistan
Turks and Caicos Islands
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
United States
United States Minor Outlying Islands
Uruguay
Uzbekistan
Vanuatu
Venezuela
Viet Nam
Virgin Islands (British)
Virgin Islands (U.S.)
Wallis and Futuna Islands
Western Sahara
Yemen
Serbia
Zambia
Zimbabwe