RV 8 with Dry Ice Condenser, coated (Manual Lift)
RV 8 with Dry Ice Condenser, coated
The IKA Rotary Evaporator range gets a new family member - the RV 8. This new distilling system completes the existing series by adding a functional basic model. The manual lift, with ambidextrous design, allows for precise positioning of the glassware. Digital displays for rotation speed and heating bath temperature allow for optimal control of all distilling processes. New clamp mechanism to simplify the changing of evaporation flasks.
Manual lift with integrated safety “lift-out-function“
New clamp mechanism
Water/oil heating bath with integrated ergonomic carrying handles
Key-button with locking function for the heating bath temperature
Speed range 5 - 300 rpm
Single-hand operation; ambidextrous design
Adjustable immersion angle
Additional user safety through reduced 24 V power requirements within the unit
Compatible with the complete range of IKA RV 10 glassware
Package description: With heating bath HB digital and RV 10.40 Dry Ice Condenser coated
Type of cooling
Dry ice condenser
Cooling surface
620 cm2
Motor principle
DC
Speed range
5 - 300 rpm
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Lift
manual
Stroke
120 mm
Heating temperature range
room temp. - 180 °C
Heat output
1400 W
Set temperature resolution
±1 K
Filling volume max.
4 l
Dimensions (W x H x D)
510 x 490 x 345 mm
Weight
25.76 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 20
Voltage
100 - 240 V
Frequency
50/60 Hz
Power input
1500 W
DC Voltage
24 V=
More Information
Cooling System Type
Dry ice condenser
Cooling surface
620 cm2
Drive Motor
Brushless D.C Motor
Reversible direction of rotation
No
Lift
Manual
Stroke
120 mm
Speed Range
5 - 300 RPM
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Temperature range (°C)
Ambient to 180°C
Heating bath temperature range
RT-180°C
Heating bath heating power
1400 W
Heating bath setting accuracy
1K
Dimensions without glassware
510 x 490 x 345 mm
Ambient Operating Range
5 - 40°C
Permissible relative humidity (%)
80%
Weight of evaporator incl. heating bath without glass parts
25.76 kg
Protection class DIN EN 60529
IP20
Rated voltages
100 - 240 V
Frequency
50 - 60 Hz
power consumption [W]
1500 W
Line voltage
24 V
Get a Quote for
Country
Afghanistan
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua and Barbuda
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Bahamas
Bahrain
Bangladesh
Barbados
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bosnia and Herzegowina
Botswana
Bouvet Island
Brazil
British Indian Ocean Territory
Brunei Darussalam
Bulgaria
Burkina Faso
Burundi
Cambodia
Cameroon
Canada
Cape Verde
Cayman Islands
Central African Republic
Chad
Chile
China
Christmas Island
Cocos (Keeling) Islands
Colombia
Comoros
Congo
Congo, the Democratic Republic of the
Cook Islands
Costa Rica
Cote d'Ivoire
Croatia (Hrvatska)
Cuba
Cyprus
Czech Republic
Denmark
Djibouti
Dominica
Dominican Republic
East Timor
Ecuador
Egypt
El Salvador
Equatorial Guinea
Eritrea
Estonia
Ethiopia
Falkland Islands (Malvinas)
Faroe Islands
Fiji
Finland
France
France, Metropolitan
French Guiana
French Polynesia
French Southern Territories
Gabon
Gambia
Georgia
Germany
Ghana
Gibraltar
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Guinea
Guinea-Bissau
Guyana
Haiti
Heard and Mc Donald Islands
Holy See (Vatican City State)
Honduras
Hong Kong
Hungary
Iceland
India
Indonesia
Iran (Islamic Republic of)
Iraq
Ireland
Israel
Italy
Jamaica
Japan
Jordan
Kazakhstan
Kenya
Kiribati
Korea, Democratic People's Republic of
Korea, Republic of
Kuwait
Kyrgyzstan
Lao People's Democratic Republic
Latvia
Lebanon
Lesotho
Liberia
Libyan Arab Jamahiriya
Liechtenstein
Lithuania
Luxembourg
Macau
Macedonia, The Former Yugoslav Republic of
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Micronesia, Federated States of
Moldova, Republic of
Monaco
Mongolia
Montserrat
Morocco
Mozambique
Myanmar
Namibia
Nauru
Nepal
Netherlands
Netherlands Antilles
New Caledonia
New Zealand
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
Northern Mariana Islands
Norway
Oman
Pakistan
Palau
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn
Poland
Portugal
Puerto Rico
Qatar
Reunion
Romania
Russian Federation
Rwanda
Saint Kitts and Nevis
Saint LUCIA
Saint Vincent and the Grenadines
Samoa
San Marino
Sao Tome and Principe
Saudi Arabia
Senegal
Seychelles
Sierra Leone
Singapore
Slovakia (Slovak Republic)
Slovenia
Solomon Islands
Somalia
South Africa
South Georgia and the South Sandwich Islands
Spain
Sri Lanka
St. Helena
St. Pierre and Miquelon
Sudan
Suriname
Svalbard and Jan Mayen Islands
Swaziland
Sweden
Switzerland
Syrian Arab Republic
Taiwan, Province of China
Tajikistan
Tanzania, United Republic of
Thailand
Togo
Tokelau
Tonga
Trinidad and Tobago
Tunisia
Turkey
Turkmenistan
Turks and Caicos Islands
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
United States
United States Minor Outlying Islands
Uruguay
Uzbekistan
Vanuatu
Venezuela
Viet Nam
Virgin Islands (British)
Virgin Islands (U.S.)
Wallis and Futuna Islands
Western Sahara
Yemen
Serbia
Zambia
Zimbabwe