The store will not work correctly in the case when cookies are disabled.
JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
RV 8 FLEX (Manual Lift) Catalog Number: 0010003572
Availability: In stock
Please contact us
RV 8 FLEX
The rotary evaporator RV 8 is the manual basic model in the family of IKA Rotation Evaporators. It finds a multitude of uses in the chemical, pharmaceutical, and biotechnology industries, in research and development, in manufacturing and quality assurance, in laboratories, and in plant construction. Digital displays for speed and heating bath temperature enable optimum control of all distillation processes.
heating bath with 4 l volume
integrated safety lift-out function in case of power failure
package includes Woulff bottle
water/oil heating bath with carrying handles
locking button for fixing heating bath temperature
clearly legible, glass-covered, black-and-white display panel
locking mechanism: red indicator shows unlocked position of the vapor tube
manual lift for precise positioning of the glassware
adjustable immersion angle
single-handed manual lift handling, suitable for left and right-handed operators
speed range: 5 - 300 min-1
low device voltage (24V) ensures user safety
flask clamping mechanism with integrated push-off function for easy exchange of evaporation flasks
compatible with the entire range of IKA RV 10 glassware
Scope of delivery
RV 8 S099
HB digital S099
RV 05.10 Balljoint clamp
RV 10.73 Vapor tube (NS 24/40)
RV 10.8001 Seal
RV 3.4 Woulff bottle
Type of cooling
without condenser
Motor principle
DC
Speed range
5 - 300 rpm
Speed tolerance set rotation speed < 100rpm
±1 rpm
Speed tolerance set rotation speed > 100rpm
±1 %
Lift
manual
Stroke
120 mm
Heating temperature range
room temp. - 180 °C
Heat output
1400 W
Set temperature resolution
±1 K
Filling volume max.
4 l
Dimensions (W x H x D)
510 x 490 x 345 mm
Weight
22.366 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 20
Voltage
100 - 240 V
Frequency
50/60 Hz
Power input
1500 W
DC Voltage
24 V=
More Information Cooling System Type without condenser Drive Motor Brushless D.C Motor Reversible direction of rotation No Lift Manual Stroke 120 mm Speed Range 5 - 300 RPM Speed tolerance set rotation speed < 100rpm ±1 rpm Speed tolerance set rotation speed > 100rpm ±1 % Temperature range (°C) Ambient to 180°C Heating bath temperature range RT-180°C Heating bath heating power 1400 W Heating bath setting accuracy 1K Dimensions without glassware 510 x 490 x 345 mm Ambient Operating Range 5 - 40°C Permissible relative humidity (%) 80% Weight of evaporator incl. heating bath without glass parts 21.5kg Protection class DIN EN 60529 IP20 Rated voltages 100 - 240 V Frequency 50 - 60 Hz power consumption [W] 1400 W Line voltage 24 V
Get a Quote for Country Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bosnia and Herzegowina Botswana Bouvet Island Brazil British Indian Ocean Territory Brunei Darussalam Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo, the Democratic Republic of the Cook Islands Costa Rica Cote d'Ivoire Croatia (Hrvatska) Cuba Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic East Timor Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands (Malvinas) Faroe Islands Fiji Finland France France, Metropolitan French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guinea Guinea-Bissau Guyana Haiti Heard and Mc Donald Islands Holy See (Vatican City State) Honduras Hong Kong Hungary Iceland India Indonesia Iran (Islamic Republic of) Iraq Ireland Israel Italy Jamaica Japan Jordan Kazakhstan Kenya Kiribati Korea, Democratic People's Republic of Korea, Republic of Kuwait Kyrgyzstan Lao People's Democratic Republic Latvia Lebanon Lesotho Liberia Libyan Arab Jamahiriya Liechtenstein Lithuania Luxembourg Macau Macedonia, The Former Yugoslav Republic of Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia, Federated States of Moldova, Republic of Monaco Mongolia Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands Netherlands Antilles New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Mariana Islands Norway Oman Pakistan Palau Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Poland Portugal Puerto Rico Qatar Reunion Romania Russian Federation Rwanda Saint Kitts and Nevis Saint LUCIA Saint Vincent and the Grenadines Samoa San Marino Sao Tome and Principe Saudi Arabia Senegal Seychelles Sierra Leone Singapore Slovakia (Slovak Republic) Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands Spain Sri Lanka St. Helena St. Pierre and Miquelon Sudan Suriname Svalbard and Jan Mayen Islands Swaziland Sweden Switzerland Syrian Arab Republic Taiwan, Province of China Tajikistan Tanzania, United Republic of Thailand Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay Uzbekistan Vanuatu Venezuela Viet Nam Virgin Islands (British) Virgin Islands (U.S.) Wallis and Futuna Islands Western Sahara Yemen Serbia Zambia Zimbabwe