LB 916 Colibri+ Microvolume Spectrometer
LB 916 Colibri+ Microvolume Spectrometer for measurement of smallest sample volumes. On-board computer and software, 7’’ touchscreen for standalone operation. Protocols for Nucleic Acids, Proteins, Custom assays. USB host interface for optional data trans
The Colibri+ takes microvolume quantification of DNA, RNA and protein samples to a whole new level. The system has been designed to help you accelerate your research combining ultra-fast measurement in less than 3 seconds with intuitive 7-inch touchscreen stand-alone operation.
Get confidence in the quality of your sample with reliable UV/VIS spectroscopy from as low as 1 µL of sample.
Colibri+ benefits at a glance:
- Fast measurement: read your samples in less than 3 seconds.
- Reliable results: CV of absorbance < 1%.
- Broad detection range:
- 2 – 20,000 ng/μl for ds DNA and
- 0.06 – 600 mg/ml for BSA, saving you precious time by avoiding manual pipetting errors.
- Stand-alone operation: 32 GB onboard memory, no computer required.
- Intuitive operation: 7” colour touchscreen and a wide variety of preprogrammed protocols simplify operation of the system.
- Easy pipetting of samples: Sample Guide Light enables accurate pipetting, even in poor light conditions.
Technical Details
| Minimum Sample Size | 1 µL |
|---|---|
| Detection Range dsDNA | 2 - 20,000 ng/µL |
| Detection Range BSA | 0.06 - 600 mg/mL |
| Path Length | 0.5 and 0.05 mm |
| Measurement Time | < 3 sec |
| Display | 7" glove compatible colour LCD touchscreen |
| Light Source | Pulsed Xenon flash lamp |
|---|---|
| Detector | 2,048 CMOS |
| Wavelength Range | 190 - 1,000 nm |
| Wavelength Accuracy | 1.3 nm |
| Absorbance Accuracy | 3.0% (at 0.75 A at 300 nm) |
| Absorbance Range (10 mm equivalent) | 0.04 - 400 A |
| Spectral Resolution | 1.5 nm (FWHM at Hg 253.7 nm) |
| Detection Area Material of Construction | Stainless steel & quartz window with hydrophobic treatment |
|
Dimensions (W x D x H) |
206 x 333 x 166 mm |
|---|---|
| Weight | 3.5 kg (7.8 lb) |
| Lamp | Xenon Flashlamp |
| Power |
Input: AC 100 - 240 V, 50/60 Hz Output: DC 24 V, 2.08 A |
| Certifications | CE, RoHS |
| Sample Format | ≥ 1µl |
|---|---|
| Wavelength Accuracy | ± 1.3 nm |
| Wavelength range | 190 - 1000nm |
| Absorbance Range | 0.04 to 400A |
| Absorbance Accuracy | 3.0% (at 0.75 A at 300 nm) |
| Light Source | Pulsed Xenon flash lamp |
| Detection Limit (dsDNA) | 2 – 20,000 ng/µL |
| Detector | 2,048 CMOS |
| Dimensions | 206 x 333 x 166 mm |
| Pathlength | 0.5 mm and 0.05 mm |