My Cart
My Quotes

MBI Winpact Parallel System (FS-05 Series)

Catalog Number:
FS-05-220
Availability: In stock
Please contact us

MBI Winpact Parallel System (FS-05 Series)

Winpact Parallel Fermentation System is the ultimate and true parallel system for your parallel experiment. Whether you need to run two identical experiments or different experiments at once, the duo heating system allows you to run two thermostat heating, two dry heating or one thermostat and one dry heating simultaneously.

This state-of-the-art fermenter/bioreactor is constructed with the upmost versatility and flexibility to work with all types and sites of Winpact vessels. The remote control software can control up to 16 fermentors for true parallel operation.

A. Single control interface for left and right vessel

B. USB port for easy data transfer

C. Power switch

D. 8 x Assignable & speed adjustable peristaltic pumps

E. Adjustable air flow meter

 

MajorScience Winpact Parallel Fermentation System (FS-05)

 

Features

Controller:

  • Duo heating system, thermostat and dry heating combined in one
  • True Parallel System, 1 controller controls 2 vessels
  • Five Interchangeable types of autoclavable glass vessel
  • Control up to 16 systems from a single interface
  • Compatible with microbial and cell culture applications
  • Intuitive user interface for short learning time
  • Ethernet communication with Winpact SCADA software, and IP addressing
  • Full selection of optional devices available
  • Compatible with solid state vessel with auto vessel angle control mechanism

 

Autoclavable glass vessel:

  • Five Interchangeable types of autoclavable glass vessel
  • Compatible with vessel volume from 0.5L to 20L

  • Remote control software connects up to 16 systems (total 32 vessels) at the same time via PC
  • Intuitive Winpact interface for easy operation

 

1.Single wall dish bottom vessel, 1L

2.Double jacketed dish bottom vessel, 3L

3.Single wall air lifter vessel, 5L

4.Double jacketed air lifter vessel, 5L

5.Single wall dish bottom vessel with heating blanket, 5L

6.Single wall plain bottom vessel with heating base unit, 10L

7.Solid State, 5L

 

Control panel

10.4" Color touch-screen interface

Communication port

Remote software control through Ethernet, up to 16 systems per PC

Data export through USB port

Analog AUX port for system extension

Program storage

Up to 59,994 process programs

Log data storage

Up to 100 process monitoring data files

Cabinet material

ABS front panel and painted iron housing

Dimension

Footprint: W x L = 15.75" x 21.61" (400 mm x 549 mm); Height: 29.14" (740 mm)

Rated voltage

220V~; 50/60 Hz, 10A, 2000W

Weight

Approx. 114.6 lb (52 kg)

Inlet gas flow-meter

0,0.1-1 LPM (500 ml); 0, 0.2-2.5 LPM (1 L); 0, 1-10 LPM (3, 5 L); 0, 2-25 LPM (10 L); 0, 6-50 LPM (15, 20 L)

Sparger

L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels);

Center-located sparger (solid state)

Baffle

316L stainless steel baffles

• 0.5-3L vessel: fixed, unmovable

• 5L and above vessel: removable

Heating

1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump)

2. Dry heating system : external devices (heating blanket or heating base unit)

Cooling

Built-in water module and external water circulator (optional)

Range

- FS-V-A/ B / SA05P series: 5℃ (41℉) above coolant up to 60℃ (140℉)

- FS-V-C series (Double Jacketed): 5℃ (41℉) above coolant up to 60℃ (140℉)

- FS-V-C series (Single Wall): without temp control

- FS-V-D series : 5℃ (41℉) above coolant up to 90℃ (194℉)

* Antifreeze is required to apply

Probe

Platinum RTD probe (PT-100), non autoclavable

Control mode

Manual or programmable 15-step PID control

Drive

Removable top brushless motor

Speed range

a. For Pitched blade impeller: 30-300 rpm

b. For Rushton impeller: 30-1800 rpm(0.5, 1L); 30-1200 rpm(3, 5L); 30-1000 rpm(10L); 30-700 rpm(15, 20L)

c. For Broken type/Spiral type/Anchor type impellers (only for FS-V-SA05 vessel): 1 – 60 rpm**

Resolution

1 rpm increment

Impeller

2 impellers for 0.5-1 L vessel and 0.5-5 L Double Jacketed Vessel

3 impellers for 3 L vessel and above; for 10 L Double Jacketed Vessel

Note: customized impellers are available upon ordering

Control mode

Manual or programmable 15-step PID control with adjustable deadband

Range

0 -14 (2-12 for maximum precision)

Resolution

0.01 pH

Probe

Gel-filled electrode, autoclavable

Control mode

Manual/acid start/progrmmable 15-step PID control

Range

0-200%, Control range: 0-100%, adjustable  

Resolution

0.1%

Probe

Polarographic DO sensor; autoclavable

Control mode

 

 • 2-stage DO cascade response

a. Increase or decrease agitation speed 

b. Supply external oxygen source (oxygen enrichment module required, optional device) 

c. Adjust DO level using gas mixing control (gas mixing station module required, optional device)

• Substrate feeding strategy

• DO Stat with smart feeding technology

Measurement range

± 2000 mV

Resolution

1 mV    

Probe

Gel-filled electrode: autoclavable    

Probe

316L stainless steel protector with insulated PTFE tube; autoclavable, adjustable sensitivity control

Control mode

Foam: on/off switch

Level: on/off switch control with wet/dry probe set up

Pump number

4 built-in Watson Marlow pumps per vessel (total 8);

Total 4 external pumps expandable:

• 2 external pumps: MU-D series required (optional)

• 2 external pumps: 4-20mA or DC 0-10V analog input 

**The minimum speed varies from 1-5 rpm depending on the medium viscosity.

Motor type

Precise stepping motor; minimum speed is 1 rpm

Speed range

0 - 65 rpm

Resolution

1 rpm

Control mode

Manual or programmable 15-step feeding control; pump can be assigned  for acid, base, antifoam and substrate

Device type

316L stainless steel condenser

 

More Information
Control unit

Control panel

10.4" Color touch-screen interface

Communication port

Remote software control through Ethernet, up to 16 systems per PC

Data export through USB port

Analog AUX port for system extension

Program storage

Up to 59,994 process programs

Log data storage

Up to 100 process monitoring data files

Cabinet material

ABS front panel and painted iron housing

Dimension

Footprint: W x L = 15.75" x 21.61" (400 mm x 549 mm); Height: 29.14" (740 mm)

Rated voltage

220V~; 50/60 Hz, 10A, 2000W

Weight

Approx. 114.6 lb (52 kg)

Aeration

Inlet gas flow-meter

0,0.1-1 LPM (500 ml); 0, 0.2-2.5 LPM (1 L); 0, 1-10 LPM (3, 5 L); 0, 2-25 LPM (10 L); 0, 4-50 LPM (15, 20 L)

Sparger

L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels);

Center-located sparger (solid state)

Baffle

Removable 316L stainless steel baffles

Temperature

Heating

1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump)

2. Dry heating system : external devices (heating blanket or heating base unit)

Cooling

Cooling coil valve and an external chiller

Range

- with FS-V-A/B/SA05P series and FS-V-C054 double jacketed vessel: 5°C (41°F)

above coolant up to 60°C (140°F)

- with FS-V-D series : 5°C (41°F) above coolant up to 90°C (194°F)

*FS-V-C053 single wall vessel without temp control

Probe

Platinum RTD probe (PT-100), non autoclavable

Control mode

Manual or programmable 15-step PID control

Agitation

Drive

Removable top brushless motor

Speed range

a. For Pitched blade impeller: 30-300 rpm

b. For Rushton impeller: 30-1800 rpm(0.5, 1L); 30-1200 rpm(3, 5L); 30-1000 rpm(10L); 30-700 rpm(15, 20L)

c. For Broken type/Spiral type/Anchor type impellers (only for FS-V-SA05 vessel): 1 – 60 rpm**

Resolution

1 rpm increment

Impeller

2 impellers for 0.5-1 L vessel and 0.5-5 L Double Jacketed Vessel

3 impellers for 3 L vessel and above; for 10 L Double Jacketed Vessel

Note: customized impellers are available upon ordering

Control mode

Manual or programmable 15-step PID control with adjustable deadband

pH

Range

0 -14 (2-12 for maximum precision)

Resolution

0.01 pH

Probe

Gel-filled electrode, autoclavable

Control mode

Manual/acid start/progrmmable 15-step PID control

DO

Range

0-200%, Control range: 0-100%, adjustable  

Resolution

0.1%

 Probe

Polarographic DO sensor; autoclavable

Control mode

 

2-stage DO cascade response (manual or program mode)

a. Increase or decrease agitation speed 

b. Supply external oxygen source (oxygen enrichment module required, optional device) 

c. Adjust DO level using gas mixing control (gas mixing station module required, optional device)

Substrate feeding strategy

ORP (optional)

Measurement range

± 2000 mV

Resolution

1 mV    

Probe

Gel-filled electrode: autoclavable    

Foam / level

Probe

316L stainless steel protector with insulated PTFE tube; autoclavable, adjustable sensitivity control

Control mode

Foam: on/off switch

Level: on/off switch control with wet/dry probe set up

Peristaltic pump

Pump number

4 built-in Watson Marlow pumps per vessel (total 8); Total 1 to 4 external pumps

(MU-D series required,  optional)

Motor type

Precise stepping motor; minimum speed is 1 rpm

Speed range

0 - 65 rpm

Resolution

1 rpm

Control mode

Manual or programmable 15-step feeding control; pump can be assigned  for acid, base, antifoam and substrate

Exhaust

Device type

316L stainless steel condenser

Write Your Own Review
You're reviewing:MBI Winpact Parallel System (FS-05 Series)
You may also be interested in the following product(s)
Catalog Number Product Name Price Qty
FS-V-A Double Jacked Dish Bottom Vessel (FS-V-A series) 500ml-10L
Please contact us
FS-V-B Single Wall Dish Bottom Vessel (FS-V-B series) 1-10L
Please contact us
FS-V-C Air Lifter Vessel (FS-V-C series) 5L only, single wall or double jacketed
Please contact us
Serie FS-V-B Single Wall Dish Bottom Vessel with Heating Blanke (FS-V-B series) 1 - 20L
Please contact us
FS-V-D Single Wall Plain Bottom Vessel with Heating Base Unit (FS-V-D series) 3 - 10L
Please contact us
FS-V-SA05P Solid State (FS-V-SA05P) 5L only
Please contact us