ADAM-MC2 Cell Counter
ADAM-MC2 Automated Fluorescence Cell Counter
The ADAM-MC2 is a new standard in automated fluorescence cell counting. Utilizing sensitive fluorescence dye staining (PI or AO/PI), LED optics, and CMOS detection technologies, it delivers accurate and reliable cell analysis in under 25 seconds. The system measures total cells, viable cells, non-viable cells, and viability percentage through automated image analysis — combined with a disposable microfluidic chip for simple, easy, and cost-effective operation.
Core Features
Principle of Viability Measurement
The ADAM-MC2 uses two fluorescence staining methods:
- PI (Propidium Iodide) Staining: PI is a membrane-impermeant dye that stains the nuclei of non-viable cells. Viable cells exclude PI. Total cell count is determined by PI-stained nuclei after lysis solution treatment.
- AO/PI (Acridine Orange / Propidium Iodide) Staining: AO stains all nucleated cells (viable and non-viable), while PI stains only non-viable cells. This dual-stain approach provides total cell count and viability in a single measurement.
After staining, the ADAM-MC2 automatically takes fluorescent images and processes them through integrated image analysis software. Two types of disposable chips are available: 2-channel and 4-channel configurations.
Cell Therapy Applications
The ADAM-MC2 serves as a QC device to monitor cell numbers and viability throughout the cell therapy manufacturing process:
- Source tissue → Cell isolation → Cell expansion → Cell harvest → Infusion to patients
Compatible cell types include:
- Stem cells
- CAR-T cells
- CAR-NK cells
- Adipose-derived stem cells
- Whole blood cells
- PBMCs (peripheral blood mononuclear cells)
- Aggregated and irregular-shaped cell lines
Accuracy & Reproducibility
Independent validation confirms high correlation and repeatability:
- Flow cytometry correlation: R² = 0.9976 (SH-SY5Y cells)
- Repeatability across concentrations: Low, medium, and high cell concentrations show consistent CV values under 4%
- Viability comparison: SH-SY5Y, Jurkat, and HeLa cells treated with H₂O₂ show comparable viability results between ADAM-MC2, flow cytometry, and manual counting
Technical Specifications
| Specification | Details |
|---|---|
| SKU / Cat. No. | ADAM-MC2 |
| Analysis Time | < 25 sec / test (4-channel) < 50 sec / test (2-channel) |
| Loading Volume | 13 µL / test (4-channel) 23 µL / test (2-channel) |
| Measuring Volume | 3.4 µL / test (4-channel) 8.6 µL / test (2-channel) |
| Measurement Range (PI) | 5 × 10⁴ – 4 × 10⁶ cells/mL |
| Measurement Range (AO/PI) | 5 × 10⁴ – 2 × 10⁷ cells/mL |
| Staining Method | Propidium Iodide (PI) or Acridine Orange / PI (AO/PI) |
| Detection Technology | CMOS detection with LED optics |
| Light Source | 4W Green LED |
| Focusing | Auto-focusing |
| Image Analysis | Automated integrated software |
| Chip Type | Disposable microfluidic chip (2-channel or 4-channel) |
| Dimensions (L × W × H) | 277 × 276 × 270 mm |
| Net Weight | 7.0 kg |
Related Accessories
- AccuChip Kit (4-channel): Cat. No. AD4K-200 — Total cell counting by PI with lysis solution
| Analysis time | < 25 sec/test (4 ch) |
|---|---|
| Loading sample volume | 13µL/test (4 ch) |
| Measuring volume | 3.4 µL/test (4ch) |
| Measuring range | 5 X 10E4 to 4 X 10E6 cells/mL(PI) 5 X 10E4 - 2 X 10E7 cells/mL (AO/PI) |
| Focusing | Auto-focusing |
| Net Weight | 7.0 kg |
| Dimensions | (L x W x H) 277 x 276 x 270 mm |
| Laser | 4W Green LED |
| Catalog Number | Product Name | Price | Qty |
|---|---|---|---|
| AD4K-200 | Accuchip 4x Kit (max 400 tests) with Accustain Solution |
$1,034.00
|
|
| DHC-N01-50 | c-chip disposable hematocymeter (Neubauer) (50 Slides / 100 Tests / 100um) |
$325.00
|
|